Electrical Characteristics
Part No: EAB-0955-0327-45P5.0
Rated Voltage
|
3VDC
|
Operating Voltage
|
2~5VDC
|
*Sound Output at 10cm
|
≥80dB
|
*Current Consumption
|
≤50mA
|
Resonant Frequency
|
2700Hz
|
Coil Resistance
|
12±3Ω
|
Operating Temperature
|
-20℃~+80℃
|
Storage Temperature
|
-30℃~+85℃
|
Weight
|
0.1g
|
Housing Material
|
Black PPO
|
Environmental Protection Regulation
|
RoHS
|
Welding method
|
Artificial welding /wave soldering
|
DIMENSIONS(UNIT: mm) Tolerance: ±0.5mm Except Specified
Note: Dust sticker on the top
RELIABLY TEST
ITEM
|
TESTING CONDITION
|
VARIANCE AFTER TEST
|
High Temperature Test
|
After being placed in a chamber with 85±2℃ for 96 hours and then being placed in natural condition for 2 hours.
|
Allowable variation of SPL after test: ±10dB.
|
Low Temperature Test
|
After being Placed in a chamber with -30±2℃ for 96 hours and then being placed in natural condition for 2 hours.
|
Allowable variation of SPL after test: ±10dB.
|
Humidity Test
|
Stored in the temperature humidity: 60±5℃ 90%--95% environment for 96 hours, and then placed into?storage at room temperature for 2?hours after the?test.
|
Allowable variation of SPL after test: ±10dB.
|
Temperature Cycle Test
|
After being placed in a chamber with -30±2℃ for 30 minutes, products shall be placed at room temperature(25℃±10℃).After 15 minutes at this temperature, products shall be placed in a chamber at +85±2℃.After 30 minutes at this temperature, products shall be return to room temperature (25℃±10℃) for15 minutes. After 20 above cycles, products shall be measured after being placed in natural condition for 2 hours.
|
Allowable variation of SPL after test: ±10dB.
|
Drop Test
|
The front and side from a height of 100mm only drop in the 4cm thickness of theboard?3 times each.
|
Allowable variation of SPL after test: ±10dB.
|
Vibration Test
|
After being applied vibration of amplitude of 1.5mm with 10 to 55 Hz band of vibration frequency to each of 3 perpendicular directions for 2 hours.
|
Allowable variation of SPL after test: ±10dB.
|
Solderability Test
|
Lead terminals are immersed in rosin for 5 seconds and then immersed in solder bath of 260±5℃ for 3±0.5 seconds (Except the edge of terminals).
|
95% min. lead terminals shall be wet with solder
|
Continuous electricity test
|
Temperature: room temperature 25 ℃
Voltage: rated voltage 3 V
Frequency: the rated frequency for 4.0 KHZ
Time: 500 hours
|
Allowable variation of SPL after test: ±10dB.
|
Erminal Strength
Pulling Test
|
The force of 9.8N(1.0kg) is applied to each terminal in axial direction for
10 seconds.
|
No visible damage and cutting off.
|
Typical Frequency Response Curve
TESTING METHOD
Standard Measurement conditions
Temperature:25±2℃ Humidity:45-65%
Acoustic Characteristics:
The oscillation frequency, current consumption and sound pressure are measured by the
measuring instruments shown below
In the measuring test, buzzer is placed as follows: